800-874-2811 | Contact Us
       
  • Language

INDOOR AIR QUALITY IAQ MONITOR, Q-TRAK

Providing a comfortable, safe and healthy indoor environment is an increasingly important concern. Good air quality increases concentration and productivity. It can also reduce lost days due to absence. TSI's Q-TRAK™ IAQ Monitor provides quick, accurate information to assess key IAQ parameters.

Features and Benefits

  •  Simultaneously  CO2, CO, temperature and humidity measurements
  •  Calculates dew point, wet bulb and percent outside air 
  •  Large graphic display
    •  Displays up to 5 measurements 
    •  On-screen messages and instructions 
    •  Supports 12 different languages 
  •  One instrument with multiple plug-in probe options including VOC’s and air velocity 
  •  Store up to 39 days of data collected at one-minute log intervals 
  •  TRAKPRO™ data analysis software provided for data logging, analysis and documenting results 
  •  Bluetooth communications for transferring data or remote polling 

Applications

  •  IAQ investigations 
  •  Industrial hygiene surveys 
  •  Baseline trending and screening 
  •  Building commissioning 
  •  Tracking down emissions to their source (point source location) 
 To request information on TSI's Q-Trak Indoor Air Quality Monitors including instrument literature, a system demonstration, a quotation, etc., please click here

Q-TRAK Indoor Air Quality Monitor 7575

TSI's Q-TRAK™ IAQ Monitor Model 7575 provides quick, accurate information to assess key IAQ parameters.

100mm Rotating Vane Probe, Model 995

Rotating Vane Probe, 100 mm, Velocity, Temp.

801760 Large Carry Case for Multi-Function Meter and Multiple Probes

Large Carry Case

IAQ Probe Model 980

IAQ Probe Model 980  Range 0 to 5000 ppm C0 2 0 to 95% RH 14 to 140ºF (-10 to 60ºC) Accuracy ±3% of reading or ± 50 ppm ±3% of RH ±0.5%ºF (±0.3ºC) Resolution 1ppm CO 2 0.1% RH 0.1ºF (0.1ºC) Probe Dimensions Length 7.0 in. (17.8 cm) Diameter 0.75 in. (

Portable Printer Model 8934

Accessory fixed head Portable Printer.

Thermal Anemometer Straight Probe Model 964

Air Velocity Probe, Straight, Velocity, Temp., Humidity

Thermo Anemometer Articulated Probe Model 966

Air Velocity Probe, Articulated, Velocity, Temp., Humidity

Thermo Anemometer Probe Model 962

Air Velocity Probe, Articulated, Velocity, Temperature

Thermo Anemometer Straight Probe Model 960

Air Velocity Probe, Straight, Velocity, Temperature

TRAKPRO™ Data Analysis Software

TRAKPRO™ Data Analysis Software is a Windows®-based software program that works with a variety of TSI data logging instruments. This unique software helps you pre-program instruments, store and organize your test data, and generate detailed graphs and reports needed to effectively communicate results.

SERVICE INFORMATION

APPLICATION NOTES

 Bluetooth Communications for 9565 and 7575 (TSI-150)
 Bluetooth Communications for 9565 and 7575 (TSI-150-A4)
 Converting Standard Velocity to Actual Velocity (TSI-109)
 Converting Standard Velocity to Actual Velocity (TSI-109)
 Draft Rate: A Determining Factor in the Quantification of Human Comfort (TSI-142)
 Draft Rate: A Determining Factor in the Quantification of Human Comfort (TSI-142)
 Field Calibration for Select TSI®, Alnor®, and Airflow™ Instruments Products (TSI-146)
 Heat Flow Calculations (TSI-124)
 Heat Flow Calculations (TSI-124)
 NDIR CO2 Sensing Technology (TSI-037)
 NDIR CO2 Sensing Technology (TSI-037-A4)
 Percent Outdoor Air Calculation and Its Use (TSI-138)
 Percent Outdoor Air Calculation and Its Use (TSI-138)
 Photo-Ionization Detection (PID) Technology (TSI-147)
 Photo-Ionization Detection (PID) Technology (TSI-147-A4)
 PID Response Factors for VOCs (TSI-148)
 PID Response Factors for VOCs (TSI-148-A4)
 Turbulence Intensity Measurements (TSI-141)
 Turbulence Intensity Measurements (TSI-141)
 Volatile Organic Compounds Probe Maintenance (TSI-149)
 Volatile Organic Compounds Probe Maintenance (TSI-149-A4)

CASE STUDIES

 Carbon Monoxide Poisoning Tracked to Faulty Pool Heater Q-Trak Case Study #1

HANDBOOKS

 HVAC Assessment Handbook (2007)
 Indoor Air Quality Handbook (2011)
 Indoor Air Quality Handbook (2011-A4)

MANUALS

 Model 7575 (DE)
 Model 7575 (FR)

FREQUENTLY ASKED QUESTIONS

show/hide all answers
  1. Does the CO sensor respond to gases other than carbon monoxide?
  2. How can non-USA customers get calibration gases?
  3. How fast do the sensors respond to changes?
  4. How long is the warranty on the Q-TRAK™ indoor air quality monitor?
  5. How many calibrations can be done with the TSI calibration kit?
  6. How should I dispose of empty calibration gas cylinders?
  7. Is it possible to lengthen the cable between the probe and the instrument?
  8. Is the Q-TRAK™ Indoor Air Quality Monitor intrinsically safe?
  9. What are the measurement ranges of the Q-TRAK™ Indoor Air Quality Monitor?
  10. What happens if my batteries die during operation?
  11. What is the warm-up time of the Q-TRAK™ Indoor Air Quality Monitor?