PIV SYSTEM PLIF
The TSI Planar Laser-Induced Fluorescence (PLIF) system provides non-intrusive, global measurements of scalar quantities such as temperature, concentration, pH, and species. Fluorescence measurements are routinely applied in research areas such as combustion, mixing, spray analysis, contaminant mass transfer, and plasma physics. The TSI PLIF system is engineered on a flexible platform built for expansion, and advanced analysis algorithms are incorporated into a user-friendly environment for simple, accurate quantification of the property of interest based on the measured fluorescence intensity field. The PLIF system can be seamlessly coupled with a TSI PIV system for simultaneous global velocity measurements, thus providing information on heat and mass fluxes. Features and Benefits
- Provides global measurements of scalar quantities such as concentration, temperature, pH, and species
- Advanced analysis algorithms to account for camera noise, background signals, spatial variations in laser sheet intensity, temporal variations in laser pulse energy
- User-programmable image analysis schemes for maximum experimental flexibility
- Full range of camera support, including all TSI intensified and un-intensified cameras
- Seamless integration with TSI PIV systems for simultaneous global velocity measurements
- Excitation wavelength flexibility from UV into IR
Applications
- Spray analysis
- Mixing studies
- Contaminant mass transfer
- Combustion diagnostics
Included Items
- PLIF laser (specific model depends upon species being measured)
- CCD camera (specific model depends upon application; includes camera lens, all interface cables, camera frame grabber)
- INSIGHT™ 3G-LIF Data Acquisition, Analysis and Display Software Package
- Light sheet optics (and optional Laser Light Arm)
- Optical filter(s) (specific PLIF filter depends on species being measured)
- LASERPULSE™ Synchronizer (Model 610035)
- All associated manuals
To request more information about TSI's Particle Image Velocimetry (PIV) System, including a price quotation, a system demo, product literature, etc. click here.
To learn more about PIV instrumentation and the many areas of research this system is involved in, attend TSI's Fluid Mechanics Webinar Series presented by our experts. Visit www.tsi.com/FMwebinars.
 |
TSI Computers integrate the latest advances in computer technology, including processing and memory storage, in order to provide the fastest, most flexible PIV and/or PLIF system available. |
 |
INSIGHT™ 3G-Global software package process Stereo PIV, PLIF and Global Spray image capture, analysis and display software on .NET platform
|
 |
INSIGHT™ 3G-LIF software package processes PLIF Image Capture, analysis and display software on .NET platform. |
 |
TSI LASERPULSE Mini-YAG Laser Model YAG120-BSL |
 |
TSI LASERPULSE Mini-YAG Laser Model YAG15-15 |
 |
TSI LASERPULSE YAG Laser Model YAG190-BSL |
 |
TSI LASERPULSE Mini-YAG Laser Model YAG30-15 |
 |
TSI LASERPULSE Mini-YAG Laser Model YAG50-15 |
 |
The LASERPULSE Synchronizer Model 610035 from TSI is a programmable master timing control unit for use in Particle Image Velocimetry (PIV) applications. |
.jpg) |
LASERPULSE Synchronizer Model 610036 The LASERPULSE Synchronizer Model 610036 from TSI is a programmable master timing control unit for use in Particle Image Velocimetry (PIV) applications. Acting as the master controller for system components, it automates control of the timing between laser pulses, camera, camera |
 |
TSI’s LASERPULSE Light Arm is an articulated arm that offers flexibility in delivering the light sheet for PIV measurements or for other high energy laser applications. |
 |
TSI's POWERVIEW™ 1.4MP Camera offers 1376 × 1040 pixel resolution and 12-bit intensity dynamic range, short frame straddling times, and long exposure times for PIV and PLIF applications. |
.jpg) |
TSI POWERVIEW™ Plus 11MP Camera is a multi-bit, 11-megapixel, digital CCD camera designed exclusively for global flow measurements. |
.jpg) |
TSI POWERVIEW™ Plus 2MP Camera is a multi-bit, 2-megapixel, digital CCD camera designed exclusively for global flow measurements. |
.jpg) |
TSI POWERVIEW™ Plus 4MP Camera is a multi-bit, 4-megapixel, digital CCD camera designed exclusively for global flow measurements. |
 |
POWERVIEW™ Plus HS-200 Camera has 640 × 480 pixel resolution, 12-bit intensity dynamic range, along with high image capture rates up to 500 frames per second. |
 |
TSI offers a full range of optical filters, which are a critically important component of PIV and PLIF system, ensuring that the correct wavelength of light is collected by the CCD camera and that other wavelengths are rejected. |
 |
TSI Laser Power Meters provide a convenient and accurate way to measure Ar ion beam powers, to keep your LDV or PDPA system running at peak efficiency. |
 |
TSI Laser Laser Safety Goggles provide a solid protection from direct and scattered laser beams. We take the guesswork out of selection and purchase of Ar ion, YAG, and YLF safety eyewear, so you can focus on using the system. |
 |
TSI's PIV Mount Kits provide a user-friendly and rugged but precise mounting base for your PIV camera(s). Easy adjustment and long-term stability are the key features of the TSI PIV Mount Kits. |
 |
TSI Rails provide the flexibility in a sturdy support system needed for any PIV system. Various lengths are available, to customise the system to the cameras and light sheet optics used. |
 |
Remote Focus MechanismTSI Model 640050/1-R series of Remote Focus Mechanism provides the remote and precise adjustment of camera focusing tot he measurement plane in PIV/PLIF measurements |
 |
The Six-Jet atomizer from TSI is used to generate a polydisperse aerosol in high concentrations, which can be used as seed particles for PIV and LDV measurements. External controls adjust the number of active jets and dilution air flow rate. |
 |
Traverse accessories help the user get the most productivity out of their TSI traverse, while enhancing safety of operation. |
 |
Single Axis (1D) Traverse Systems are used for capturing image data at multiple planes in a flow with INSIGHT™ 3G-based PIV, HFR-PIV, PLIF, or Spray Analysis systems. These traverses are also used for capturing size and velocity profiles in a flow with a FLOWSIZER™ |
.jpg) |
TSI T2D and T2DE Two Axis (2D) Traverse Systems are used for capturing image data at multiple planes in a flow with INSIGHT™ 3G software-based PIV, HFR-PIV, PLIF, or Spray Analysis System. |
 |
Three Axis (3D) Heavy-duty Traverse Systems are used for capturing size and velocity profiles in a flow with a three-component FLOWSIZER™ software-based LDV or phase Doppler system. |
 |
Three Axis (3D) Traverse Systems are used for capturing image data at multiple planes in a flow with TSI INSIGHT™ 3G software-based PIV, HFR-PIV, PLIF, or Spray Analysis systems. |
 |
Three Axis (3D) Traverse Systems are used for capturing image data at multiple planes in a flow with INSIGHT™ 3G software-based PIV, HFR-PIV, PLIF, or Spray Analysis systems. |
BROCHURESPOSTERSSPEC SHEETSSERVICE INFORMATION
APPLICATION NOTESTECHNICAL NOTES
|
|