TIME RESOLVED PIV SYSTEMS
The Particle Image Velocimetry (PIV) technique for the first time offered experimentalists the ability to capture the instantaneous spatial nature of a flow field. TSI PIV systems, incorporating patented processing algorithms such as Hart Correlation, have provided flow field information with very high spatial resolution for several years. The temporal resolution of PIV measurements has been limited, however, because the update rate of velocity measurements, governed by the camera frame rate and the laser pulse rate, was too low for most practical applications. The ability to measure flow field evolution as a function of time has always been of great interest to experimentalists.
To obtain detailed temporal and spatial information about flow properties, TSI has developed an integrated, high-frame rate PIV system that makes flow measurements with very high update rates. The detailed temporal statistics obtained globally from these measurements offer unique information about flow dynamics, flow transport and the motion of structures in a flow.
Features and Benefits
- New master control unit automates timing control for high speed cameras and other devices
- High-speed cameras designed specifically for high frame rate applications
- INSIGHT™ Data Acquisition, Analysis and Display Software provides complete system control
- Remote focusing and Scheimpflug adjustment enables remote system alignment
- Flow measurements with capture rates as high as 10 kHz
Applications
- Measure flow field evolution
- Obtain unique information on flow dynamics, flow transport, and motion of structures in a flow
Included Items
- High Repetition Rate Nd:YLF or Nd:YAG laser (specific model depends upon application)
- High Frame Rate CMOS camera (specific model depends upon application; includes camera lens, all interface cables, camera frame grabber)
- INSIGHT™ 3G-2DTR or INSIGHT™ 3G-STTR Data Acquisition, Analysis and Display Software Package
- Light sheet optics (and optional Laser Light Arm)
- Optical filter
- LASERPULSE™ Model 610035 Synchronizer
- All associated manuals
To request more information about TSI's Particle Image Velocimetry (PIV) System, including a price quotation, a system demo, product literature, etc. click here.
To learn more about PIV instrumentation and the many areas of research this system is involved in, attend TSI's Fluid Mechanics Webinar Series presented by our experts. Visit www.tsi.com/FMwebinars.
 |
INSIGHT™ 3G-2DTR software package process PIV image capture, analysis and display software on .NET platform |
 |
INSIGHT™ 3G-Global software package process Stereo PIV, PLIF and Global Spray image capture, analysis and display software on .NET platform
|
 |
INSIGHT™ 3G-STTR software package processes Stereo PIV image capture, analysis and display software on .NET platform. |
 |
TSI Model YLF-HS Dual laser provides hgh repetition rate for laser pulse from 1000 Hz to 10000 Hz with energy level up to 12 mJ so that proper illumination of the flow field can be achieved. |
 |
TSI Model YAG-HS high repetition rate PIV laser offers a single laser with double pulse capability. The integrated power supply and chiller unit is part of the system. |
 |
The LASERPULSE Synchronizer Model 610035 from TSI is a programmable master timing control unit for use in Particle Image Velocimetry (PIV) applications. |
.jpg) |
LASERPULSE Synchronizer Model 610036 The LASERPULSE Synchronizer Model 610036 from TSI is a programmable master timing control unit for use in Particle Image Velocimetry (PIV) applications. Acting as the master controller for system components, it automates control of the timing between laser pulses, camera, camera |
 |
TSI’s LASERPULSE Light Arm is an articulated arm that offers flexibility in delivering the light sheet for PIV measurements or for other high energy laser applications. |
 |
The LASERPULSE Synchronizer Model 610034 from TSI is a programmable master timing control unit for use in Particle Image Velocimetry (PIV) applications. |
 |
Laser light sheet optics from TSI provide flexibility in the light sheet divergence angle and the beam waist location via careful selection of focal lengths. for PIV and PLIF applications. |
 |
POWERVIEW™ HS-2000 Camera has 1024 × 1024 pixel resolution, 10-bit digitization and 8-bit output, along with frame rates from 2,000 to 120,000 frames per second with the standard 2.6 GB memory and FireWire® interface. |
 |
POWERVIEW™ HS-3000 Camera has 1024 × 1024 pixel resolution, 10-bit digitization and 8-bit output, along with frame rates from 3,000 to 250,000 frames per second with the standard 2.6 GB memory and FireWire® interface. |
 |
POWERVIEW™ HS-650 Camera has 1280 × 1024 pixel resolution, 10-bit digitization, along with image capture rates from 636 to 40,000 frames per second. |
 |
POWERVIEW™ Plus HS-200 Camera has 640 × 480 pixel resolution, 12-bit intensity dynamic range, along with high image capture rates up to 500 frames per second. |
 |
TSI offers a full range of optical filters, which are a critically important component of PIV and PLIF system, ensuring that the correct wavelength of light is collected by the CCD camera and that other wavelengths are rejected. |
 |
TSI Laser Power Meters provide a convenient and accurate way to measure Ar ion beam powers, to keep your LDV or PDPA system running at peak efficiency. |
 |
TSI Laser Laser Safety Goggles provide a solid protection from direct and scattered laser beams. We take the guesswork out of selection and purchase of Ar ion, YAG, and YLF safety eyewear, so you can focus on using the system. |
 |
TSI's PIV Mount Kits provide a user-friendly and rugged but precise mounting base for your PIV camera(s). Easy adjustment and long-term stability are the key features of the TSI PIV Mount Kits. |
 |
The Oil Droplet Generator (TSI Model 9307) is used to produce large quantities of oil droplets for seeding flows when making PIV or LDV measurements. The large droplet output is especially useful for seeding high-speed flows. |
 |
TSI Rails provide the flexibility in a sturdy support system needed for any PIV system. Various lengths are available, to customise the system to the cameras and light sheet optics used. |
 |
TSI offers a full range of seed particles to satisfy even the most difficult measurement requirements. Available in a full range of materials and sizes, TSI seed particles maximize the potential of PIV and LDV systems. |
 |
TSI's Model 9302 single-jet atomizer generates a polydisperse aerosol stream from a compressed air source. External pressure control and a flexible outlet tube allow the user to put the right amount of aerosol right where its needed. |
 |
The Six-Jet atomizer from TSI is used to generate a polydisperse aerosol in high concentrations, which can be used as seed particles for PIV and LDV measurements. External controls adjust the number of active jets and dilution air flow rate. |
 |
Traverse accessories help the user get the most productivity out of their TSI traverse, while enhancing safety of operation. |
 |
Single Axis (1D) Traverse Systems are used for capturing image data at multiple planes in a flow with INSIGHT™ 3G-based PIV, HFR-PIV, PLIF, or Spray Analysis systems. These traverses are also used for capturing size and velocity profiles in a flow with a FLOWSIZER™ |
.jpg) |
TSI T2D and T2DE Two Axis (2D) Traverse Systems are used for capturing image data at multiple planes in a flow with INSIGHT™ 3G software-based PIV, HFR-PIV, PLIF, or Spray Analysis System. |
 |
Three Axis (3D) Heavy-duty Traverse Systems are used for capturing size and velocity profiles in a flow with a three-component FLOWSIZER™ software-based LDV or phase Doppler system. |
 |
Three Axis (3D) Traverse Systems are used for capturing image data at multiple planes in a flow with TSI INSIGHT™ 3G software-based PIV, HFR-PIV, PLIF, or Spray Analysis systems. |
 |
Three Axis (3D) Traverse Systems are used for capturing image data at multiple planes in a flow with INSIGHT™ 3G software-based PIV, HFR-PIV, PLIF, or Spray Analysis systems. |
BROCHURESPOSTERSSPEC SHEETSSERVICE INFORMATION
APPLICATION NOTESTECHNICAL NOTES
|
|